VIP
Current research Abstracts
Hypodontia
New techniques
Procedure tutorials
Suppliers Guide
Instructions
Literature
Szmukler-Moncler S, Salama H, Reingewirtz, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature. J Biomed Meter Res (Appl Biomater) 43:192-203,1998. Pilliar RM, Lee JM, Maniatopoulos C, Observations of the effect of movement on bone ingrowth into porous-surfaces implants. Clin Orthop. 208:108-113, 1986. Lefkove MD, Beals RP. Immediate loading of cylinder implants with overdentures in the mandibular symphysis: The titanium plasma-sprayed screw technique. J Oral lmplantol 1990; 16(4):265-271. Cochran DL, Schenk RK, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible. J Biomed Mater Res. 40:1-11;1998. Tarnow DP, Emtiaz S, Classi A. Immediate loading of threated implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants 1997; 12:319-24. Schnitman PA, Whörle PS, Rubenstein JE, DaSilva JD, Wang NH. Ten-year results for Branemark implants immediately loaded with fixed prostheses at implant placement. Int J Oral Maxillofac Implants 1997; (12)4:495-503. Wöhrle PS. Single-tooth replacement in the aesthetic zone with immediate provisionalization: Fourteen consecutive case reports. Pract Periodontics Aesthet Dent 1998 Nov-Dec;10(9):1107-14; quiz 1116. Babbush CA, Kent JN, Misiek DJ. Titanium plasma-sprayed screw implants for the reconstruction of the edentulous mandible. J Oral Maxillofoc Surg 1986; 44:274-82. Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clin Oral Implants Res 1997; 8(1):48-57. Brånemark, P-I et al. A new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. Clin Implant Dent Rel Res 1999 1: 2-16. Chiapasco, M. et al. Implant-retained Mandibular overdentures with Brånemark System MKII implants. A prospective comparative study between delayed and immediate loading. Int J Oral Maxillofac Implants. 2001 Jul-Aug;16(4):537-46. Melas,F. et al. : Oral health impact on daily performance in patients with implant-stabilized over-dentures and patients with conventional dentures. Int J Oral Maxillofac Implants 2001 16: 700-712. Røynesdal, Anne-K. et al.: A Comparative clinical investigation of 2 early loaded ITI Dental Implants supporting an overdenture in the mandible. Int J Oral Maxillofac Implants 2001 16: 246-251. Szmukler-Moncler, S. et al. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000 11: 12-25.
Disclaimer - ©2001 Copyright - Science Communication Service